EPTech

On-Site Workshop: 1-Day Hazardous Area Classification (Groups II & III)

This workshop provides a sound understanding of how Group II (flammable gases, liquids and vapours) and Group III (combustible dusts) hazardous areas are classified. 

This workshop is suitable as first time or refresher training for personnel requiring a comprehensive understanding of hazardous area classification.

Potential sources of ignition are often taken into hazardous locations where flammable liquids, gases, vapours and dusts are generated, processed, handled and stored.  These flammable substances can easily be ignited from an arc, spark or heat.  It is essential that you avoid accidental ignition of these flammable substances.

Based on the current Australian Standards, trainees will receive an introduction to hazardous area legislation and a good understanding of how these hazardous areas are classified.

Ensure you remain compliant* and maintain your hazardous area skills and knowledge by booking this essential workshop today.

Workshop topics:

  • Legislation and compliance
  • How Group II and Group III hazardous areas are classified
  • How to read hazardous area classification drawings
  • Equipment Protection Levels (EPLs)
  • How to apply EPLs to select hazardous area electrical equipment

Upon completion of this workshop trainees should:

  • Be up-to-date with changes that have occurred in the relevant hazardous area Australian Standards
  • Understand legislation and compliance
  • Have existing hazardous area knowledge reinforced
  • Have a sound understanding of how Group II and Group III hazardous areas are classified
  • Understand hazardous area classification drawings
  • Understand Equipment Protection Levels (EPLs)
  • Understand how to apply EPLs to select hazardous area electrical equipment
Date of Workshop: Date to be agreed
Time: 7.00-7.30 am registration
7.30 am to 4.30 pm workshop (To be agreed)
Breaks : 8.30-8.35 am              Brain recovery
9.30 —9.45 am            Tea/coffee
11.00 —11.05 am         Brain recovery
12 noon —12.40 pm      Lunch
1.40 —1.45 pm            Brain recovery
2.45 —3.00 pm            Tea/coffee
Venue: At your factory
Catering: You provide all tea, coffee, soft drinks and light lunches
CPD: This workshop provides 9 hours of Continuous Professional Development (CPD) to assist practicing professional engineers and technicians to maintain and develop their hazardous area technical skills and knowledge.
Recognition: ‘Esso Training and Procedures Group has endorsed “Explosion Protection Technology” as an approved provider of “Hazardous Area Wiring” refresher training for Esso maintenance and designated contractor technicians.’
Marlene Hutty, EAPL Training Coordinator
Full Workshop fee: Workshops presented from 1st January to 31st December 2012
$380.00 + $38.00 (GST) = $418.00 per person
Minimum number of trainees is 10 and maximum is 25.
Workshop fee includes:
  • Comprehensive workshop notes
  • Workshop certificate
Early Bird Discount: Save an amazing $55.00 per person by paying within 14 days after the start of the workshop
Early bird fee: $330.00 + $33.00 (GST) = $363.00 per person
Payment: Full workshop fee: Payment must be received within 28 days after commencement of workshop.
Early bird discount: Payment must be received within 14 days after commencement of workshop to receive discounted fee.
MasterCard, Visa, cheque or EFT are accepted.
Substitutes: If an enrolled person is unable to attend a substitute is allowed at no extra charge. Details must be faxed or emailed in advance.
Transfers: Enrolment transfers to another workshop are not permitted.
Cancellations: A $82.50 fee applies to each cancelled workshop place received in writing more than two weeks prior to the agreed commencement date of the training workshop.  Regrettably, no refunds are available after this date or if a trainee fails to attend and no substitute fills the place.  The workshop folder will be posted to the trainee. A letter will be mailed following payment in full advising a 40% discount applies on one future 1-day workshop place for each cancelled or no-show booking.  This offer is valid for 12 months and no further discounts will apply.
Set-up: Venue needs to be set-up the afternoon prior to commencement of workshop.  Seating should be at tables arranged in a U shape with six additional large tables for demonstration equipment and documentation.  Click HERE to see suggested room layout. Note boardroom tables are unsuitable.
Names: A list of all enrolled trainees names is required two weeks prior to commencement of the workshop. Please provide the following for each trainee:
  • Trainee name for name badge and workshop folder
  • Name (if different to name badge) for certificate
  • Job title
  • Contact phone number, fax and or email address

Workshop outline:

1. Introduction

  • Hazardous areas
  • Who is responsible
  • Statute laws and Standards

2. Hazardous Area Classification

  • Ignition curves
  • Zone classification - Group II
  • Gas classification - equipment group
  • Temperature classification - T Class
  • Ambient temperature range of explosion protected equipment
  • Area classification - Group II
  • Combustible dusts - Group III

3. Sources of Ignition

  • Ignition Triangle

4.  Selection of Equipment

  • Equipment Protection Levels (EPLs)
  • Equipment selection for Group II
  • Equipment selection for Group III

5.  Self Appraisal

  • Appraisal questionnaire
  • Appraisal questionnaire answers

6. Discussion

Delivery of workshop:

Workshops are presented using PowerPoint slides, a video clips, video tapes and real hazardous area electrical equipment.

Workshop Author and Presenter

Colin Baker is a practicing professional engineer, qualified workplace assessor (Certificate IV) and workplace trainer who has been involved with surge protection, intrinsic safety and hazardous area installations since 1970.  He has worked for some of the major manufacturers of hazardous area instrumentation and has gained significant surge protection and hazardous area experience through designing, installing, commissioning and inspecting equipment and installations.

Colin has also provided training and technical support to many chemical, petrochemical and public utility companies around the world and has written and presented numerous papers locally and internationally.

An H Class Licensed Electrical Inspector (Vic) and Accredited Auditor (QLD), Colin is qualified to inspect hazardous area electrical installations under the 2009 Victoria Electricity Safety (Installation) Regulations and the 2002 Queensland Electrical Safety Regulation.

He sits on the joint Australian/New Zealand Standards sub-committees for the preparation of standards on Intrinsic Safety and industrial hazardous area trucks. Colin is also on the Petroleum Industry Contractors Association electrical sub-committee.

Explosion Protection Technology is a leading independent and Australian owned consulting and training organisation founded by Colin. The company specialises in the safety of hazardous area electrical installation based on the current Australian Standards including:

  • Classifying hazardous areas
  • Checking electrical installations located in hazardous areas
  • Assisting clients to obtain certification of hazardous area electrical equipment
  • Running hazardous area training workshops
 *Continuing education or training is required - before Sep 2012: see Clause 1.7 of AS/NZS2381.1:2005 and Clause 4.7 of AS/NZS61241:14:2005; after Sep 2012: see clause 4.4 of AS/NZS600079.14:2009 and clause 4.2 of AS/NZS600079.17:2009

 

 

 

Call Today

(03) 9707 3110

TRAINING WORKSHOPS
1-Day Basic
Melbourne (Sunshine)
28 Aug 2012
Sydney (Artarmon)
21 Aug 2012
2-Day Simplified
Melbourne (Sunshine)
29 - 30 Aug 2012
Sydney (Artarmon)
22 - 23 Aug 2012
3-Day Comprehensive
Melbourne (Blackburn North)
4 - 6 Dec 2012
Melbourne (Sunshine)
29 - 31 May 2012
Sydney (Artarmon)
19 - 21 June 2012
Sydney (Liverpool)
27 - 29 Nov 2012
ON-SITE WORKSHOPS
1-Day Classification
1-Day Classification Groups II and III
1-Day Basics
1-Day Group II
1-Day Groups II and III
2-Day Simplfied
2-Day Group II
2-Day Groups II and III
3-Day Comprehensive
3-Day Group II
3-Day Groups II and III
Copyright © 2011 Explosion Protection Technology Privacy Policy